September is here, and if you are wondering how to safely test your emergency heat setting before freezing weather arrives, doing so now while the weather is still mild is the smartest move you can make. Your heat pump has likely been running flawlessly to cool your home through the end of summer, but that quiet, efficient operation can easily mask a hidden problem: broken auxiliary heat strips. When you wait until a mid-winter storm to discover your backup heat isn't working, you risk a sudden no-heat emergency right when you need warmth the most.

Testing your system during this September fall-prep window gives you a crucial buffer. It allows you to identify hidden electrical failures and schedule repairs long before the peak heating rush overwhelms local technicians. Here at Kelley & Dawson Service, after 60 years of providing HVAC solutions to Wichita homeowners, our team regularly sees sharp late-fall temperature drops where a system that was working perfectly in mild October suddenly fails during a harsh November freeze. If you need help preparing your system for the seasonal shift, our HVAC and air conditioning services team is ready to ensure your home stays comfortable.

Proactive testing is the only way to know for sure that your home is ready for winter. Heat pumps are incredibly efficient machines, but they rely on a secondary heating source when the weather turns extreme. By taking a few minutes to safely test your thermostat now, you take control of your winter comfort and protect your home from unexpected temperature drops.

What Happens When Outdoor Temperatures Drop Below Freezing?

To understand why this test is so important, it helps to know exactly how your system reacts to extreme cold. Heat pumps do not generate heat the way a gas furnace does; instead, they extract ambient heat from the outside air and move it indoors. This process is highly efficient in mild weather. However, when outdoor temperatures drop below 35 to 40 degrees Fahrenheit, there is simply less ambient heat available to extract.

As the system loses efficiency in these below freezing temperatures, it automatically triggers your electric resistance heaters—often called auxiliary heat or "Aux Heat"—to supplement the warming process. These high-voltage heat strips sit inside your indoor air handler and act very much like the glowing coils in a toaster or a giant space heater, providing the extra boost needed to keep your indoor temperature stable.

Heating ModeHow It WorksWhen It Activates
Normal Heat PumpExtracts heat from outdoor air and moves it indoors.Mild to cool weather (above 35°F).
Auxiliary Heat (Aux)Electric strips turn on automatically to supplement the heat pump.When temperatures drop below 35°F or the indoor temp falls 2°F below the setpoint.
Emergency Heat (Em Heat)Bypasses the outdoor unit entirely; runs only the indoor electric strips.Manually selected at the thermostat during a heat pump failure.

It is important to clarify the difference between automatic "Aux Heat" and the manual "Emergency Heat" setting on your thermostat. Aux heat runs alongside your outdoor unit to help it keep up. Emergency heat shuts down the outdoor unit completely and relies 100% on the indoor electric strips. During normal winter operation, you might also notice your system going through defrost cycles to melt ice off the outdoor coils. If you are ever curious about this normal winter behavior, seeing steam coming from an outdoor heat pump is actually a sign that the defrost cycle is working exactly as intended.

The Danger of Skipping Your Pre-Winter Heat Strip Check

The biggest risk with auxiliary heat strips is that they sit completely dormant for months at a time. Throughout the spring and summer cooling seasons, these electrical components do absolutely nothing. During this long period of inactivity, electrical relays can stick, sequencers can degrade, and the heating elements themselves can develop faults without showing any outward signs of failure.

Many homeowners assume that if their air conditioner worked fine in August, their heater will work fine in December. Unfortunately, a standard cooling tune-up might not always catch isolated heating element issues if the specific high-voltage heating sequence isn't initiated and tested. If you skip a functional test during your September fall-prep routine, you leave your home vulnerable to sudden indoor temperature drops the first time the system tries to call for backup heat.

Hidden failures to watch out for:

  • Stuck sequencers: These components time the activation of the heat strips so they don't all turn on at once and trip your breaker. If they fail, the strips won't ignite.
  • Broken elements: Just like a lightbulb filament, the actual heating coils can break or burn out over time.
  • Corroded wiring: Summer humidity inside the air handler can lead to minor corrosion on the high-voltage connections.

Confirming the operation of your backup heat now prevents expensive emergency dispatch fees later. If you prefer to have an expert handle the pre-season inspection, scheduling professional system maintenance ensures every electrical relay and heating element is tested safely by a licensed technician.

Step-by-Step: How to Safely Test Your Emergency Heat Setting at the Thermostat

Testing your backup heat does not require any tools, and you should never attempt to open your HVAC equipment to look at the wiring. As a 60-year multi-generational HVAC company, we explicitly warn homeowners never to open electrical panels or probe wires. High-voltage electric strips carry a dangerous amount of current. Keep all testing strictly at the thermostat level.

Follow this safe, step-by-step sequence to verify your system is ready for below freezing temperatures:

  1. Step 1: Establish a baseline. Turn your thermostat to the standard "Heat" mode and set it to your normal comfortable temperature. Wait until the system reaches this baseline temperature and turns off. This ensures the primary heat pump is functioning.
  2. Step 2: Switch to Emergency Heat. Locate the mode switch or button on your thermostat and change it from "Heat" to "Emergency Heat" (often abbreviated as "Em Heat"). You may see a small indicator light turn on.
  3. Step 3: Raise the target temperature. Adjust the thermostat setpoint 2 to 3 degrees higher than the current room temperature. This forces the system to call for immediate heat.
  4. Step 4: Check the airflow. Wait roughly 5 to 10 minutes, then place your hand near a supply vent. Feel the air coming from the ductwork. It should feel noticeably hotter and drier than the air normally produced by your heat pump.
  5. Step 5: Return to normal operation. Once you have confirmed warm airflow and the initial burning dust smell has cleared, switch the thermostat back to the standard "Heat" mode immediately. Do not leave the system in Emergency Heat.
Safe Thermostat Testing Sequence for Emergency Heat
Safe Thermostat Testing Sequence for Emergency Heat

Interpreting the Results: Smells, Sounds, and Airflow

When you activate your emergency heat for the first time during your September fall-prep, the system will behave a bit differently than it does during normal operation. Understanding these differences helps you determine whether your test was successful or if you need to call for repairs.

Why Does It Smell Like Burning Dust?

The most common cause for concern during this test is a distinct burning odor coming from the vents. This is entirely normal. Throughout the spring and summer cooling seasons, microscopic dust, pet dander, and lint settle on the dormant electric heating coils inside your air handler. When you switch to Emergency Heat, those coils rapidly heat up to hundreds of degrees, instantly incinerating the accumulated dust.

This creates a temporary burning smell that typically dissipates within 15 to 30 minutes of running the system. It is a harmless, temporary occurrence and is actually a very good indicator that your heat strips are successfully drawing power and generating heat.

How Warm Should the Air Feel?

Standard heat pump air often feels lukewarm to the touch—usually around 85 to 95 degrees Fahrenheit. While this is plenty warm to heat a house, it doesn't always feel "hot" against your skin. Emergency heat, however, bypasses the outdoor compressor entirely and acts like a giant electric space heater. The air coming from your vents during this test should feel significantly hotter and drier than standard operation, often exceeding 100 degrees Fahrenheit.

Warning signs to watch for: While a brief dusty odor is normal, you should stay alert for signs of trouble. If the smell persists for more than an hour, if it smells distinctly like melting plastic or burning electrical wires, or if the air blowing from the vents remains completely cold after 10 minutes, the test has failed and the system requires professional attention.

When to Skip the DIY Test and Call a Professional

While testing your thermostat is a safe and necessary part of home maintenance, there are strict boundaries for when a homeowner must stop testing and call for licensed HVAC repair. High-voltage heat strips require specialized training to diagnose safely. If your system fails to perform during the test, do not attempt to open the air handler to investigate the cause.

Stop your test and call a professional immediately if you experience any of the following scenarios:

  • No heat after 10 minutes: If the thermostat clicks and the indoor fan blows, but the air remains stubbornly cold after 10 minutes, the heating elements or sequencers have likely failed.
  • Tripped circuit breakers: If your electrical panel's circuit breaker trips immediately upon switching to Emergency Heat, you have a dead short in the high-voltage wiring. Do not repeatedly reset the breaker, as this can cause a fire.
  • Electrical burning odors: A dusty smell is normal; a sharp, acrid smell of melting plastic, ozone, or visible smoke is a serious electrical hazard.
Symptom During TestLikely CauseAction Required
Brief smell of burning dustNormal dust burning off dormant coilsWait 15-30 minutes for smell to clear.
Air feels lukewarm or coldFailed sequencer or broken heat stripCall a licensed professional.
Immediate breaker tripElectrical short in the high-voltage systemLeave breaker off; call a professional.
Acrid, melting plastic smellOverheating wires or failing blower motorTurn system off immediately; call a professional.

If you encounter any of these warning signs before below freezing temperatures arrive, you have successfully used your testing window to catch a major problem early. Reach out to our Wichita HVAC repair services team to have a licensed technician safely diagnose and resolve the electrical fault.

Frequently Asked Questions About Emergency Heat Settings

How do I know if my emergency heat is working?

The most direct way to check is to switch the thermostat to the Em Heat setting, raise the temperature a few degrees, and feel the air coming from your vents. Within 5 to 10 minutes, the airflow should feel significantly warmer and drier than standard heat pump air. Additionally, a brief burning dust smell during the first test of the season is a strong indicator that the electric strips have successfully ignited.

Why does my emergency heat smell like burning?

Dust, pet hair, and airborne debris naturally collect on the electric heating elements inside your air handler during the long summer months. When you activate the heat strips for the first time in the fall, the high temperatures instantly burn this dust off, creating a temporary odor. This smell is completely normal and should disappear after about 15 to 30 minutes of continuous operation.

When should I call a professional for my heat pump?

You should call a licensed technician if the air remains cold while in Em Heat mode, if the system immediately trips a circuit breaker, or if the burning smell lasts longer than 30 minutes. Furthermore, if you notice an acrid smell resembling melting plastic or electrical ozone, turn the system off immediately and call for professional diagnostics, as this indicates a severe electrical fault.

Should I test my emergency heat?

Yes, testing it proactively in early fall ensures the backup system is ready before a harsh winter freeze hits. Heat pumps handle mild weather easily, which can mask a broken backup heating system. By running a quick thermostat test before below freezing temperatures arrive, you give yourself plenty of time to schedule any necessary repairs without paying premium emergency dispatch fees.

How long should I run emergency heat for a test?

You should run it only long enough to confirm warm airflow and clear the initial dust smell, which typically takes about 10 to 15 minutes. Once you feel hot air coming from the supply vents and the dusty odor begins to fade, immediately switch your thermostat back to the standard "Heat" mode to resume normal, energy-efficient operation.

Is it safe to leave emergency heat on all winter?

No, it is extremely inefficient and will cause your monthly energy bills to skyrocket. Emergency heat relies entirely on electric resistance strips, which consume significantly more electricity than the standard heat pump compressor. You should only use the Em Heat setting during a primary heat pump failure while you are waiting for an HVAC technician to arrive for repairs.

Ensure Your Home Stays Warm Through the First Hard Freeze

Taking 15 minutes during your September fall-prep to test your thermostat's emergency heat setting provides incredible peace of mind. By proactively verifying that your backup heat strips are functional, you remove the guesswork from winter preparation and ensure your family won't be left shivering during the first major cold front of the year. Knowing your system is fully operational allows you to face the changing seasons with confidence.

If your DIY test revealed cold air, tripped breakers, or persistent electrical smells, do not wait for the weather to worsen. Act quickly to resolve the issue while the weather is still forgiving. For absolute certainty that your system is ready for the harsh months ahead, schedule professional system maintenance today and let our licensed experts secure your home's comfort.